7000 Watt (23,870 BTUH ) @ 20°C
76313
Please Call for Pricing
NO SPEC AVAILABLE AT THIS MOMENT
NO SPEC AVAILABLE AT THIS MOMENT
10,500 Watt (35,805 BTUH ) @ 20°C
76413
Please Call for Pricing
CHILLER - (SINGLE PHASE)
- 3 HP 230V/1PH/60Hz – 29 Amps
- Cooling Capacity: 35,827 BTU/hr, (10,500 Watts)
- 2HP Stainless Steel Centrifugal Pump
- 10-15 GPM at 40 PSI Max
- Internal Bypass Flow
- External Bypass Valve System
- Air Cooled Condenser
- Accurate microprocessor control with dual digital readout for temperature and pressure/flow
- User settable alarms for process temperature, pressure, flow rate, and ambient temperature.
- Condensate Insulate Wrap entire cooling loop
- Pump protection my means of pump bypass valve
- Compressor protection through high and low refrigerant pressure cutouts
- 7 Gallon water reservoir
- Heavy duty, four wheel swivel locking casters provide easy maneuverability
- Easy access air filter: Reusable filter can quickly be cleaned put back into operation
- Reduced Noise and energy savings by utilizing load-dependant fan cycling
- Dimensions: 30.5”D, 37”W, 42”H
- 580lbs
- No Resovoir Refill Option Available
- Decibel level - Pump Only 60db
- Decibel leve - Fan, Compressor, Pump - 69db
CHILLER - (SINGLE PHASE)
- 3 HP 230V/1PH/60Hz – 29 Amps
- Cooling Capacity: 35,827 BTU/hr, (10,500 Watts)
- 2HP Stainless Steel Centrifugal Pump
- 10-15 GPM at 40 PSI Max
- Internal Bypass Flow
- External Bypass Valve System
- Air Cooled Condenser
- Accurate microprocessor control with dual digital readout for temperature and pressure/flow
- User settable alarms for process temperature, pressure, flow rate, and ambient temperature.
- Condensate Insulate Wrap entire cooling loop
- Pump protection my means of pump bypass valve
- Compressor protection through high and low refrigerant pressure cutouts
- 7 Gallon water reservoir
- Heavy duty, four wheel swivel locking casters provide easy maneuverability
- Easy access air filter: Reusable filter can quickly be cleaned put back into operation
- Reduced Noise and energy savings by utilizing load-dependant fan cycling
- Dimensions: 30.5”D, 37”W, 42”H
- 580lbs
- No Resovoir Refill Option Available
- Decibel level - Pump Only 60db
- Decibel leve - Fan, Compressor, Pump - 69db
5200 Watt (17743 BTUH ) @ 20°C
79716P
Please Call for Pricing
Chiller w/ Positive Displacement Pump
- 1.5 HP
- 230/1/60
- 4 GPM (20-100PSI)
- (6 Gallons - 22.7 Liter)
- 17743 BTUH (5200 Watt) @ 20 Degree C
- 12 FLA
- 6 FT Cord & Plug,
- Castors for portability.
- 348 LBS (158KG)
Chiller w/ Positive Displacement Pump
- 1.5 HP
- 230/1/60
- 4 GPM (20-100PSI)
- (6 Gallons - 22.7 Liter)
- 17743 BTUH (5200 Watt) @ 20 Degree C
- 12 FLA
- 6 FT Cord & Plug,
- Castors for portability.
- 348 LBS (158KG)
16,384 Watt (55,920 BTUH ) @ 20°C
PCA500
Please Call for Pricing
Cool Max 5 Ton PCA500A-X
Key Specifications:
- Cooling Capacity: 17,935 W / 61,200 BTU/hr @ 35°C
- Set Point Range: -6° to 26.6°C
- Temperature Stability: +- 0.6°C
- Power Requirements: 208-230V, 3 phase, 60Hz, 35.2 A (460/480 available, specify)
- Reservoir Capacity (gallons/liters): 11 gallons / 42 liters with Low Liquid Level alarm
- Overall dimensions (L x W x H): 48 x 35 x 61" (122 x 89 x 155 cm)
- Pump type: 1.5HP stainless steel pump
- Maximum Pump Pressure: 35 psi
- Maximum Flow Rate: 12 GPM (10-25 GPM available)
- Refrigerant type: R410A
- Process Connections: 1.5"
Chiller Features:
- Compact micro-channel all aluminum air-cooled condensers for increased durability
- High efficiency, low noise fans (air-cooled units only) with integral condensers for reduced operating noise and increased efficiency
- Stainless steel brazed plate evaporators with flow and temperature safeties to guard against freezing
- Low voltage 24 VDC control keeps the control circuit signals free from AC interference
- C-UL 508A industrial control panel with single point electrical connection
- Removable inlet air filter is easily cleaned and protects condenser coils to assume maximum efficiency
Controller Features:
- Password protected operational parameters
- Start-to-start anti-cycle timer prevents short-cycling of compressor while minimizing unnecessary off periods
- Display of compressor and pump running hours helps with scheduling routine maintenance
- Loss of phase/phase reversal/phase imbalance alarm
- Pump test button allows for quick and easy pump rotation check from the main control panel
- Temperature deviation warnings provide an adjustable deviation set point to indicate abnormal operation of chiller or process equipment without shutting down the chiller
Cool Max 5 Ton PCA500A-X
Key Specifications:
- Cooling Capacity: 17,935 W / 61,200 BTU/hr @ 35°C
- Set Point Range: -6° to 26.6°C
- Temperature Stability: +- 0.6°C
- Power Requirements: 208-230V, 3 phase, 60Hz, 35.2 A (460/480 available, specify)
- Reservoir Capacity (gallons/liters): 11 gallons / 42 liters with Low Liquid Level alarm
- Overall dimensions (L x W x H): 48 x 35 x 61" (122 x 89 x 155 cm)
- Pump type: 1.5HP stainless steel pump
- Maximum Pump Pressure: 35 psi
- Maximum Flow Rate: 12 GPM (10-25 GPM available)
- Refrigerant type: R410A
- Process Connections: 1.5"
Chiller Features:
- Compact micro-channel all aluminum air-cooled condensers for increased durability
- High efficiency, low noise fans (air-cooled units only) with integral condensers for reduced operating noise and increased efficiency
- Stainless steel brazed plate evaporators with flow and temperature safeties to guard against freezing
- Low voltage 24 VDC control keeps the control circuit signals free from AC interference
- C-UL 508A industrial control panel with single point electrical connection
- Removable inlet air filter is easily cleaned and protects condenser coils to assume maximum efficiency
Controller Features:
- Password protected operational parameters
- Start-to-start anti-cycle timer prevents short-cycling of compressor while minimizing unnecessary off periods
- Display of compressor and pump running hours helps with scheduling routine maintenance
- Loss of phase/phase reversal/phase imbalance alarm
- Pump test button allows for quick and easy pump rotation check from the main control panel
- Temperature deviation warnings provide an adjustable deviation set point to indicate abnormal operation of chiller or process equipment without shutting down the chiller