-Construction of 16 ga white painted steel
-OD 58”w x 96”l x 120”h
-ID 36”w x 92”l x 80”h
-Top blower boxes to have (2) 5 HP, 208/230/460 V, 3 phase, 60 HZ, direct drive high pressure motor blower, developing 1800 CFM to 4” sp, vibration isolated
-99.99% gasket seal hepa filter mounted in blower box
- (72) PVC nozzles on walls & ceiling @ 6000 fpm each
-Hinged & gasketed doors for motor / blower & filter
-Internally mounted control system, microprocessor controlled
-No floor, ceiling mounted sensor for automatic start
- (2) 36” x 80” anodized aluminum doors, clear anodized w/ ¼” acrylic inserts, push/pull hardware, closures & electrical interlocks w/ (1) E-stop
-35% disposable prefilters in low wall mounted aluminum grilles
-60 FC flush mounted fluorescent lighting
-Unit shipped (4) sections |